18 AWG PVC najlon PVC potpuni oklopljeni TC-ER kontrolni kabel 600V

18 AWG PVC najlon PVC potpuni oklopljeni TC-ER kontrolni kabel 600V
Details:
·PVC kombinezon
·Potpuno žareni goli bakar klase B
·Pokriveno polivinil hloridom (PVC).
· Punilo (po potrebi)
·Napon: 600V
·Temperatura: Određeno na 90 stepeni mokro ili suho
· Raspon veličina: Dostupan u 18 do 10 AWG
·Standardno: UL83/UL1277
·Dostupan u 2 do 37 provodnika
·Boja: Po ICEA S-58-679 metodi 1, tabela E-2; dostupne dodatne opcije kodiranja boja
Send Inquiry
Download
Opis
Technical Parameters
Certifikacija

IEEE 1202 tray cable

PROIZVOD REAL SHOT

 

75C wet control cable
UV resistant tray cable
600V direct burial control cable

UL 1685 tray cable

18 AWG otporan na sunčevu svjetlost, VNTC kabel za nosače od pouzdanog dobavljača TC{{1}ER kabela
Ovo18 AWG PVC Najlon PVC kompletno oklopljeni TC-ER kontrolni kablje visokih-performansioklopljeni TC-ER kontrolni kabl, izdržljivKontrolni kabel otporan na sunčevu svjetlost, NEC usklađenizloženi kabl nosača, i poslujemo kao profesionalniTC-ER dobavljač kablova. Dizajnirana sa troslojnom THHN PVC-najlonskom izolacijom, potpunom aluminijskom zaštitom od Mylar folije i UV stabiliziranom crnom PVC omotačem, ova više-žica podržava otvorenu instalaciju nosača, vodove i direktnu instalaciju za industrijska kontrolna kola, ocijenjeno kontinuirano od 90 stepeni za potpune mokre i suhe lokacije.
SPECIFIKACIJE PROIZVODA

 

TC-ER control cable supplier

Opis proizvoda

 

PVC/Nylon/PVC (THHN/THWN-2), 600V kontrolni, tip TC-ER i kablovi za direktno ukopavanje sastoje se od potpuno žarenih bakarnih provodnika klase B, prekrivenih polivinil hloridom (PVC) otpornim na naftu i plin i izolacijom od prozirnog najlona ili neoklopljenog crnog PVC-a. Ovi kablovi se koriste u industrijskim energetskim ili kontrolnim krugovima stanica.

Prijave

 
  • U kanalima, kanalima, slobodnom zraku, stazama i direktnom ukopavanju, primarne instalacije uključuju nosače kablova i vanjske lokacije

  • Na vlažnim ili suhim lokacijama

  • Odobreno za industrijske opasne lokacije klase I, Div. 2 po NEC

  • Dozvoljeno za Exposed Run (ER) koji se koristi u skladu sa NEC za 3 ili više provodnika; dva vodiča bez žice za uzemljenje su samo tipa TC

Karakteristike

 
  • Ocenjeno na 90 stepeni mokro ili suvo
  • Ripcord (po potrebi)
  • Odlična otpornost na sunčevu svjetlost
  • Zadovoljava test na hladno savijanje na -25 stepeni
SPECIFIKACIJE

Conductor Count

Dostupan u 2 do 37 provodnika

Dirigent

Potpuno žareni goli bakar klase B

Gauge Sizes

Dostupan u 18 do 10 AWG

Izolacija

Prekriven polivinil hloridom (PVC).
• 14 AWG i veći su tip THHN/THWN-2
Kodiranje boja Po ICEA S-58-679 Metoda 1, Tabela E-2; dostupne dodatne opcije kodiranja boja
Punila Ne-higroskopna punila, prema potrebi za dobijanje kružnog poprečnog presjeka
štit (opcionalno) Celokupna aluminijumska poliesterska (mylar) folija u kontaktu sa 20 AWG upredenom kalajisanom bakrenom odvodnom žicom
Jakna polivinil hlorid (PVC)

Označavanje jakne

Veličine provodnika 18 AWG – 16 AWG: 00000 FT VEĆI ŽIČNI KABL XXAWG XX/C PVC/NAJLON PVC JKT (ili OS) 600V 90C VLAŽNI ILI SUVI TIP TC (ili {{5}ER) (UL) SUN RES4/BEEDE20 MMDDYYYY Veličine provodnika 14 AWG – 10 AWG: 00000 FT VEĆI ŽIČNI KABL XXAWG XX/C THHN/THWN-2 PVC JKT (ili OS) 600V 90C VLAŽNI ILI SUVI TIP TCULIR (ili S - B FT4/IEEE1202 MADE IN CHINA MMDDYYYY

Pakovanje

Ne-mote za drvo koje se može vratiti u različitim dužinama i dimenzijama

Usklađenost sa performansama

ASTM B8, ASTM B33

UL 83

UL 1277

UL 1685 (test izloženosti plamenu)

ANSI/NEMA WC 70/ICEA S-95-658

ANSI/NEMA WC 57/ICEA S-73-532

NEC

Ostale usklađenosti

EPA 40 CFR, dio 261

OSHA

RoHS-usklađen/RoHS 2 usklađen

U skladu sa REACH-

Unshielded

Conductor Count Veličina provodnika AWG Debljina izolacije
in (mm)
Jacket Thickness
in (mm)
Pribl. Ukupni prečnik
in (mm)
Pribl. Neto težina
lbs/kft (kg/km)

2

18 0.020(0.51) 0.045(1.14) 0.28(7.1) 40(56)
3 18 0.020(0.51) 0.045(1.14) 0.29(7.5 50 (69)
4 18 0.020(0.51) 0.045(1.14) 0.32(8.0) 60(84)
5 18 0.020(0.51) 0.045(1.14) 0.34(8.7) 70(99)
7 18 0.020(0.51) 0.045(1.14) 0.37(9.4) 85(126)
9 18 0.020(0.51) 0.045(1.14) 0.43(10.9) 110(158)
12 18 0.020(0.51) 0.045(1.14) 0.47(12.0) 135(199)
19 18 0.020(0.51) 0.045(1.14) 0.55(14.0) 205(298)
25 18 0.020(0.51) 0.060(1.52) 0.67(17.1) 280(414)
37 18 0.020(0.51) 0.060(1.52) 0.76(19.4) 390(573)
2 16 0.020(0.51) 0.045(1.14) 0.30(7.7) 50 (69)
3 16 0.020(0.51) 0.045(1.14) 0.32(8.1) 60(88)
4 16 0.020(0.51) 0.045(1.14) 0.35(8.8) 75(109)
5 16 0.020(0.51) 0.045(1.14) 0.37(9.5) 90 (130)
7 16 0.020(0.51) 0.045(1.14) 0.40(10.3) 115(168)
9 16 0.020(0.51) 0.045(1.14) 0.47(12.0) 145(211)
12 16 0.020(0.51) 0.045(1.14) 0.52(13.3) 185(269)
16 16 0.020(0.51) 0.060(1.52) 0.61(15.6) 255(378)
19 16 0.020(0.51) 0.060(1.52) 0.64(16.4) 295(435)
25 16 0.020(0.51) 0.060(1.52) 0.75(18.9) 380(560)
30 16 0.020(0.51) 0.060(1.52) 0.79(20.0) 440(653)
37 16 0.020(0.51) 0.060(1.52) 0.85(21.5) 530(784)
2 14 0.020(0.51) 0.045(1.14) 0.33(8.4) 60(88)
3 14 0.020(0.51) 0.045(1.14) 0.35(8.8) 80(115)
4 14 0.020(0.51) 0.045(1.14) 0.38(9.6) 100(143)
5 14 0.020(0.51) 0.045(1.14) 0.41(10.4) 120(172)
7 14 0.020(0.51) 0.045(1.14) 0.45(11.3) 155(226)
9 14 0.020(0.51) 0.045(1.14) 0.52(13.2) 195(285)
12 14 0.020(0.51) 0.060(1.52) 0.61(15.5) 265(393)
19 14 0.020(0.51) 0.060(1.52) 0.71(18.1) 400(591)
25 14 0.020(0.51) 0.060(1.52) 0.83(21.0)   515(763)
30 14 0.020(0.51) 0.060(1.52) 0.87(22.2)    605(895)
37 14 0.020(0.51) 0.080(2.03) 0.98(25.0) 765(1,138)
2 12 0.020(0.51) 0.045(1.14) 0.37(9.3) 80(117)
3 12 0.020(0.51) 0.045(1.14) 0.39(9.8) 110(157)
4 12 0.020(0.51) 0.045(1.14) 0.42(10.7) 135(198)
5 12 0.020(0.51) 0.045(1.14) 0.46(11.7) 165(240)
7 12 0.020(0.51) 0.045(1.14) 0.50(12.7) 215(318)
9 12 0.020(0.51) 0.060(1.52) 0.62(15.7) 290(431)
12 12 0.020(0.51) 0.060(1.52) 0.69(17.4) 375(553)
19 12 0.020(0.51) 0.060(1.52) 0.80(20.3) 565(840)
25 12 0.020(0.51) 0.080(2.03) 0.98(24.8) 775(1,147)
30 12 0.020(0.51) 0.080(2.03) 1.03(26.2) 905(1,344)
37 12 0.020(0.51) 0.080(2.03) 1.11(28.2) 1,090(1,622)
2 10 0.025(0.64) 0.025(0.64) 0.43(11.0) 115(169)
3 10 0.025(0.64) 0.025(0.64) 0.46(11.7) 160(231)
4 10 0.025(0.64) 0.025(0.64) 0.50(12.8) 200(295)
5 10 0.025(0.64) 0.025(0.64) 0.58(14.8) 260(385)
7 10 0.025(0.64) 0.025(0.64) 0.63(16.1) 345(511)
9 10 0.025(0.64) 0.025(0.64) 0.74(18.9) 435(647)
12 10 0.025(0.64) 0.025(0.64) 0.83(21.0) 565(836)

 

Overall Shielded

Pair Count Veličina provodnika AWG Debljina izolacije
in (mm)
Jacket Thickness
in (mm)
Pribl. Ukupni prečnik
in (mm)
Pribl. Neto težina
lbs/kft (kg/km)

2

18 0.020(0.51) 0.045(1.14) 0.28(7.2) 45(62)
3 18 0.020(0.51) 0.045(1.14) 0.30(7.5) 55(76)
4 18 0.020(0.51) 0.045(1.14) 0.32(8.1) 65(91)
5 18 0.020(0.51) 0.045(1.14) 0.34(8.8) 75(106)
7 18 0.020(0.51) 0.045(1.14) 0.37(9.4) 90(133)
9 18 0.020(0.51) 0.045(1.14) 0.43(10.9) 115(165)
12 18 0.020(0.51) 0.045(1.14) 0.48(12.1) 140(207)
19 18 0.020(0.51) 0.045(1.14) 0.56(14.1) 210(306) 
25 18 0.020(0.51) 0.060(1.52) 0.68(17.2) 285(423)
37 18 0.020(0.51) 0.060(1.52) 0.77(19.5) 395(583)
2 16 0.020(0.51) 0.045(1.14) 0.31(7.8) 55 (76)
3 16 0.020(0.51) 0.045(1.14) 0.32(8.2) 65(95)
4 16 0.020(0.51) 0.045(1.14) 0.35(8.9) 80(116)
5 16 0.020(0.51) 0.045(1.14) 0.38(9.6) 95(137)
7 16 0.020(0.51) 0.045(1.14) 0.41(10.4) 120(175)
9 16 0.020(0.51) 0.045(1.14) 0.47(12.1) 150(219)
12 16 0.020(0.51) 0.045(1.14) 0.53(13.4) 190(277)
16 16 0.020(0.51) 0.060(1.52) 0.62(15.7) 265(387)
19 16 0.020(0.51) 0.060(1.52) 0.65(16.4) 300(444)
25 16 0.020(0.51) 0.060(1.52) 0.75(19.0) 385(569)
30 16 0.020(0.51) 0.060(1.52) 0.79(20.1) 450(663)
37 16 0.020(0.51) 0.060(1.52) 0.85(21.6) 535(794)
2 14 0.020(0.51) 0.045(1.14) 0.33(8.4) 65(94)
3 14 0.020(0.51) 0.045(1.14) 0.35(8.9) 65(95)
4 14 0.020(0.51) 0.045(1.14) 0.38(9.6) 85(121)
5 14 0.020(0.51) 0.045(1.14) 0.41(10.4) 105(150)
7 14 0.020(0.51) 0.045(1.14) 0.44(11.3) 125(179)
9 14 0.020(0.51) 0.045(1.14) 0.52(13.2) 160(232)
12 14 0.020(0.51) 0.060(1.52) 0.61(15.4) 200(292)
19 14 0.020(0.51) 0.060(1.52) 0.71(18.0) 270(400)
25 14 0.020(0.51) 0.060(1.52) 0.82(20.9) 405(597)
30 14 0.020(0.51) 0.060(1.52) 0.87(22.0) 520(770)
37 14 0.020(0.51) 0.080(2.03) 0.98(24.8) 610(1,144)
2 12 0.020(0.51) 0.045(1.14) 0.37(9.3) 85(124)
3 12 0.020(0.51) 0.045(1.14) 0.39(9.8) 110(163)
4 12 0.020(0.51) 0.045(1.14) 0.42(10.7) 140(205)
5 12 0.020(0.51) 0.045(1.14) 0.46(11.6) 170(246)
7 12 0.020(0.51) 0.045(1.14) 0.50(12.6) 220(325)
9 12 0.020(0.51) 0.060(1.52) 0.62(15.6) 295(438)
12 12 0.020(0.51) 0.060(1.52) 0.68(17.3) 380(560)
19 12 0.020(0.51) 0.060(1.52) 0.80(20.2) 570(846)
25 12 0.020(0.51) 0.080(2.03) 0.97(24.6) 775(1,153)
30 12 0.020(0.51) 0.080(2.03) 1.02(26.0) 910(1,350)
37 12 0.020(0.51) 0.080(2.03) 1.10(28.0) 1,095(1,627)
2 12 0.020(0.51) 0.045(1.14) 0.43(11.0) 120(176)
3 10 0.025(0.64) 0.045(1.14) 0.46(11.7) 160(238)
4 10 0.025(0.64) 0.045(1.14) 0.50(12.8) 205(302)
5 10 0.025(0.64) 0.060(1.52) 0.58(14.7) 265(392)
7 10 0.025(0.64) 0.060(1.52) 0.63(16.0) 350(517)
9 10 0.025(0.64) 0.060(1.52) 0.74(18.8) 440(654)
12 10 0.025(0.64) 0.060(1.52) 0.82(20.9) 570(843)
 
CERTIFIKACIJE

 

600V control cable manufacturer

PACKAGING

 

VNTC tray cable specification

Roll

TC-ER cable AWG sizes

Plastic Reel

PVC/Nylon/PVC Type TC-ER 14 AWG

Mali drveni kolut

PRIMJENA

 

VNTC cable sizes
Factory Automation
control cable 18 AWG to 10 AWG
Procesna instrumentacija
TC-ER control cable datasheet
Kontrolni sistemi za tretman vode
CASE

 

PVC/Nylon/PVC TC-ER cable specs

BASF Ludwigshafen Verbund Site

VNTC cable datasheet

MWRA Deer Island Postrojenje za tretman otpadnih voda

ICEA tray cable

Siemens Electronic Works Amberg Factory

ZAŠTO ODABRATI NAS

 

30Godine iskustva
na jednom{0}}uslugi

Dongguan Greater Wire & Cable Co., Ltd. je profesionalni proizvođač kablova-razreda inženjeringa u Kini, koji isporučuje certificirana rješenja za električne kablove za građevinske, industrijske, rudarske, energetske i infrastrukturne projekte širom svijeta.

Sa fabrikom od 30.000 m², 30 proizvodnih linija, iskusnim inženjerima i timom za strogu kontrolu kvaliteta, obezbeđujemo pouzdane, sledljive i usklađene kablovske proizvode za međunarodne inženjerske aplikacije. Naši proizvodi su podržani certifikatima uključujući SAA, UL, cUL, VDE, TÜV, CE, CB, IEC, BPS i ISO.

Posvećeni smo sigurnosti, kvalitetu, transparentnosti i-dugoročnom partnerstvu. Od inspekcije sirovina do testiranja gotovog proizvoda, svaka serija je pažljivo kontrolirana kako bi se osigurale stabilne performanse i pouzdano korištenje projekta.

Ovjeren kvalitet većeg kabla -. Pouzdano snabdevanje. Inženjerska vrijednost.

VNTC tray cable supplier
 
15K
Završeni projekti
150+
stručno osoblje
15K
sretni klijenti
92+
nagrade i sertifikati
OPREMA ZA POSTROJENJU

 

UL listed PVC/Nylon/PVC control cable
 
UL listed Type TC-ER control cable
 
sunlight resistant PVC/Nylon/PVC control cable
 
wet location THHN PVC tray cable
 
dry location TC-ER control cable
 
exposed run TC-ER tray cable
 
GLOBALNI CERTIFIKATI

 

dry location THHN PVC tray cable

FOTOGRAFIJE KUPACA
 

wet location PVC/Nylon/PVC control cable

MEĐUNARODNI TRANSPORT

 

01

Sea Freight

Nudimo pouzdana rješenja pomorskog transporta za velike-narudžbe. Vaša roba je sigurno upakovana i otpremljena u kontejnerima, što osigurava isplativu-isporuku u luke širom svijeta.

02

Air Freight

Za bržu isporuku, naša usluga zračnog transporta osigurava da vaši proizvodi brzo stignu do međunarodnih odredišta, uz pažljivo rukovanje i potpuno praćenje na putu.

03

International Express

Trebate hitne pošiljke? Naša međunarodna ekspresna usluga efikasno isporučuje male i srednje narudžbe, pružajući uslugu od vrata-do-od vrata do vrata uz praćenje u stvarnom-vremenu za bezbrižnost.

sunlight resistant THHN PVC tray cable
ZADRUŽNI PARTNER

 

Tražimo kooperativnog partnera za proširenje našeg poslovanja.

multi-conductor control cable
600V TC-ER tray cable
600 volt control cable
PVC nylon PVC control cable
industrial control cable
industrial tray cable
VNTC TC-ER cable
THHN/THWN tray cable
PVC jacket tray cable
bare copper control cable
Kako sarađivati ​​sa nama?

Jednostavno podijelite svoje zahtjeve, primite naše profesionalno rješenje, potvrdite uzorke i uživajte u brzoj, pouzdanoj proizvodnji i isporuci širom svijeta - rad s nama je tako jednostavan.

Naša adresa

Zgrada 2, No. 40 Luxi 2nd Road, Liaobu Town, Dongguan City, Guangdong Province, Kina

Broj telefona

+86 136 6257 9592

+86 135 1078 4550

E-pošta

manager01@greaterwire.com

unshielded VNTC tray cable
FAQ

 

Koje prednosti protiv smetnji nudi ovaj zaštićeni TC{1}ER kontrolni kabl?
Opslužuje i niz{0}}upravljačke signalne petlje i pomoćna industrijska strujna kola, široko rasprostranjena u fabričkoj automatizaciji, stanicama opreme i sistemima ožičenja proizvodnih linija.
Zašto je ovaj kvalifikovan kao-dugotrajan kontrolni kabl otporan na sunčevu svjetlost?
Njegova specijalno formulirana crna PVC vanjska obloga pruža vrhunsku UV otpornost, sprječavajući pucanje i starenje pod dugotrajnim-izlaganjem sunčevoj svjetlosti.
Može li se ova žica slobodno instalirati kao standardni kabel za izlaganje?
Da, ispunjava pune TC-ER NEC standarde; Kablovi sa 3 ili više provodnika mogu se polagati izloženi na nosače kablova bez dodatne zaštite vodova.
Kakvu podršku možete pružiti kao osoba od povjerenjaTC-ER dobavljač kablova?
Mi isporučujemo prilagođeni broj jezgara, veleprodajne cijene, standardno pakovanje u drvenom kolutu i kompletnu tehničku dokumentaciju za sve serije TC-ER kablova za nosače.

 

Hot Tags: 18 awg pvc najlon pvc sveukupno oklopljeni tc{1}}er kontrolni kabel 600v, Kina 18 awg pvc najlon pvc kompletno oklopljeni tc-er kontrolni kabel 600v proizvođači, dobavljači, tvornica

Send Inquiry